Hvac Refrigeration Manifold

Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool


Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool
Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool

Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool    Digital Manifold Gauge HVAC Refrigeration Vacuum Temp. Pressure Leak Tester Tool

AUTOOL LM120 Digital Refrigeration Manifold is an auxiliary instrument for the installation, testing, and maintenance of refrigeration equipment such as air conditioners and cold storage. The instrument is capable of double pressure test, dual temperature test (need test clip, not include), digital readout, multi-unit switching, multi-mode function, and built-in refrigerant database.

The maximum pressure when the refrigerant changes from liquid to gas. The lowest temp when the liquid becomes gaseous. The lower the pressure and temp of the evaporation are, the more efficient the refrigeration cycle and the greater the refrigeration capacity will do.

The minimum pressure when the refrigerant changes from gas to liquid, and the maximum temp when the gas changes to liquid. The lower the pressure and temp of condensation are, the higher the efficiency of the refrigeration cycle and the greater the refrigerant capacity will do. The temperature of the AUTOOL LM120 Digital Refrigeration Manifold in the high/low-pressure pipelines of the air conditioning system. Calculate the pressure difference between the initial test pressure and the second test pressure to determine if the refrigerant is leaking. AUTOOL LM120 Digital Refrigeration Manifold can be set according to the type of refrigerant that the car needs to fill; The refrigerant filing status can be observed through a visible window.

The intelligent digital display of the test results of the pressure and temperature of the air conditioning system reduces the cost of time. For damage caused by non-human factors, AUTOOL promises to resend parts for free within 3 years. Pressure Test Unit:Kpa; Mpa; bar; inHg; PSI. Pressure Test Range:0 Kpa 6000 Kpa.

Pressure Test Accuracy:+/- 0.5 %(FS)+ 5dgt. Pressure Overload Limit:10000 Kpa (10 Mpa; 100 bar;). Vacuum Test Unit:Kpa; Mpa; bar; inHg; PSI. Vacuum Test Range: -101Kpa 0Kpa. Temperature Test Unit: °C (Celsius), °F (Fahrenheit).

Temperature Test Range: -40°C 150°C (-40°F 302°F). 0.1°C (-40°C 99.9°C), 1°C (100°C 150°C). 0.1°F (-40°F 99.9°F), 1°F (100°F 302°F).

Safety Standards For Design And Production. The pressure measured by the digtal manifold pressure tester is gauge pressure. Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).

The limit pressure is 10 Mpa (100 bar). The maximum operating pressure of standard hose is 600 PSI (approximate 4.13 Mpa, 41.3 bar).

The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar. Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed hoses does not match the pressure requirement, you can use suitable replacements for testing.

Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields. Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring. Please wear qualified protective equipment to protect user during testing. Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases. 1 PC AUTOOL LM120 Digital Refrigeration Manifold Main Unit.

This item is in the category "Business & Industrial\HVAC & Refrigeration\HVAC & Refrigeration Tools\HVAC & Refrigeration: Gauges & Probes". The seller is "lutifix_official_store" and is located in this country: CN. This item can be shipped worldwide.
  1. Brand: AUTOOL
  2. Country/Region of Manufacture: China
  3. Type: Refrigeration Manifold Gauge
  4. Manufacturer Warranty: 3 Years
  5. Refrigerant: R-12, R-123, R-12a, R-290, R-22, R-401a, R-401b, R-402a, R-402b, R-407a, R-407c, R-408a, R-409a, R-410a, R-414b, R-416a, R-422b, R-422c, R-422d, R-427a, R-500, R-502, R-507, R-600a
  6. Gauge Purpose: Pressure, Temperature, Vacuum
  7. Vacuum Units: PSI
  8. Gauge Fill: Dry
  9. Feature1: Refrigerant Filling
  10. Feature2: Evaporation Pressure&Temp.

    Test

  11. Feature4: High/Low Pressure Temp. Test
  12. Feature5: Pressure Leakage Test
  13. Pressure Test Unit: Kpa, Mpa, bar, inHg, PSI
  14. Pressure Test Range: 0Kpa ~ 6000Kpa
  15. Pressure Test Resolution: 1Kpa
  16. Vacuum Test Unit: Kpa, Mpa, bar, inHg, PSI
  17. Vacuum Test Range: -101Kpa ~ 0Kpa
  18. Vacuum Test Resolution: 1Kpa
  19. Temperature Test Unit: °C , °F
  20. Temperature Test Range: -40°C ~ 150°C (-40°F ~ 302°F)
  21. Color: Gray
  22. Items Included: User Manuel
  23. Item Width: 120MM(4.72Inch)
  24. Item Length: 210MM(8.27Inch)
  25. Model: LM120
  26. Item Weight: 1KG
  27. Features: Digital